When doing power installation, CENTER 360 can provide same special helps. When doing insulation test, it can provide 250V, 500V and 1000V source for the test and under each range it can supply more 1mA current to feed the capacitance load. With the autorange function, it can measure up to 4000 MegaOhm with the resolution of 1K Ohm.
When doing the continuity test, the tester can source 200mA to distinguish the bad connections. By its built-in autorange function, on the same function range it can measure up to 4K Ohm with resolution of 0.1 Ohm.
These characteristics are also specified in the safety regulations in CE document.
Function
|
Range
|
Resolution
|
Accuracy
|
AC Voltage
|
600V
|
0.1V
|
±1% rdg + 3dgts
|
DC Voltage
|
600V
|
0.1V
|
±1.5% rdg + 3dgts
|
Resistance
|
400Ω~4000Ω
|
0.1Ω~1Ω
|
±1% rdg + 5dgts
|
Insulation
|
4Ω~4000MΩ
|
1KΩ~1MΩ
|
±3% rdg + 5dgts
|